International Research journal of Management Science and Technology

  ISSN 2250 - 1959 (online) ISSN 2348 - 9367 (Print) New DOI : 10.32804/IRJMST

Impact Factor* - 6.2311


**Need Help in Content editing, Data Analysis.

Research Gateway

Adv For Editing Content

   No of Download : 117    Submit Your Rating     Cite This   Download        Certificate

SEISMIC ASSESSMENT OF RC STRUCTURE WITHOUT SHEAR WALL AND WITH SHEAR WALL AT DIFFERENT LOCATIONS

    2 Author(s):  DR J BHATTACHARJEE, ENG. VIVEK KUMAR KUMAR

Vol -  11, Issue- 5 ,         Page(s) : 51 - 58  (2020 ) DOI : https://doi.org/10.32804/

Abstract

Human life face so many disasters, natural and manmade. One of the natural disasters is earthquake which occurs suddenly without any previous warning and cause huge damage to the building. One of the aspects of building with resistance to the earthquake load is shear walls. Shear Walls have more in plane strength and stiffness and can support large amount of lateral load and gravity load in same time. These walls are mainly constructed for tall buildings and it gives more strength and safety to the structure with external lateral loads. In this study a G+11 stories building is considered, and analysis has been for different location of shear walls for seismic Zone 5.

[1] Ravi Kumar K. Sundar Kumar: "Analysis and Design of Shear Wall for an Earthquake Resistant Building using ETABS “International Journal for Innovative Research in Science & Technology, Volume 4,
Issue 5, October 2017.
[2] A.B. Karnale and Dr. D. N. Shinde: Comparative Seismic Analysis of High Rise and Low Rise RCC Building with Shear Wall, International Journal of Innovative Research in Science, Engineering and
Technology, September 2015..
[3] Mr.K.L. lovaraju and dr. K.V.G.D. Balaji: “Effective location of shear wall on Performance of building frame Subjected to earthquake load “International advanced research journal in science, engineering and technology vol.2, issue 1, January 2015.
[4] Chowdary, P.V.S. and Pandian, S.M. (2014): “A Comparative Study on RCC Structure with and without Shear Wall”, International Journal for Scientific Research & Development, IJSRD, Vol. 2, No.2.
[5] Varsha. R. Harne: "Comparative study of strength of RC Shear wall at different location on multistoried Residential building", International Journal of civil Engineering Research. ISSN 2278-3652 Volume5, Number 4(2014) pp 391-400.
[6] P.P. Chandurkar, DR. P.S. Pajgade: "Seismic analysis of RCC building with and without shear wall" IJMER, Vol.3, Issue 3, may- June 2013, pp- 1805 -1810,2013.
[7] Poornima Detal: May 2017 Seismic Analysis of RC Residential Multi-Storey Building for Different Locations of Shear Wall.

*Contents are provided by Authors of articles. Please contact us if you having any query.